Authentication

What it is

Authentication is the check a system makes before it accepts a
claimed identity: someone says “I am this account”, and the system
asks for evidence that only the holder of that account should be
able to produce. Engineers often shorten it to authn, and interfaces
call the same moment “sign in” or “log in”.

Identification is the claim itself, such as typing a username.
Authentication is the evidence for that claim. Authorization is the
separate decision, made afterwards, about what the now-known
identity is allowed to do. Even HTTP blurs the line: RFC 9110 names
status code 401 “Unauthorized”, yet defines it as a request that
lacks valid authentication credentials, and obliges the server to
send a WWW-Authenticate header describing how to supply them. The
code for “we know who you are, and the answer is still no” is 403
Forbidden.

```http
HTTP/1.1 401 Unauthorized
WWW-Authenticate: Bearer realm="api"
```

The evidence comes in kinds, usually called factors. Something you
know is a password or a PIN. Something you have is a phone, a
hardware security key or a private key file. Something you are is a
fingerprint or a face. Multi-factor authentication combines two
different kinds, so that a thief who obtains one still lacks the
other. Two passwords are still one factor.

Much of it involves no person at all. Services present API tokens to
each other, and SSH shows the machine-shaped version clearly: RFC
4252 makes “publickey” the only method every implementation must
support, and the client proves it holds a private key by signing
with it, so the key never crosses the network. Single sign-on moves
the check elsewhere. With OpenID Connect an identity provider
authenticates the user and hands the application a signed ID token,
so the application never sees a password. Passkeys, built on the W3C
Web Authentication API, keep a private key on the device, scoped to
one website, and sign the server’s challenge together with the
origin the browser is actually talking to, so a lookalike domain
receives nothing it can replay.

Why it matters

Every other control assumes this one worked. Permissions, audit
logs, rate limits and billing are all keyed on an identity, and if
the check that set the identity is weak, each of them faithfully
applies to the wrong party. A log line saying an administrator
deleted a table records which account did it, and only good
authentication turns that into who.

The practical decision is how strong the check must be for each
door, and NIST SP 800-63B gives the clearest scale to decide with.
Its first assurance level, AAL1, accepts a single factor. AAL2
requires two factors, and a verifier at that level must offer at
least one phishing-resistant option. AAL3 requires a
phishing-resistant authenticator whose private key cannot be
exported. The guideline is blunt about one popular choice: codes
typed in by hand, whether sent by text message or shown in an app,
are not phishing-resistant, because nothing ties the typed digits to
the site that asked for them.

Revision 4 of the same document, which superseded revision 3 on 1
August 2025, also settled several arguments about passwords. A
password used as the only factor must be at least 15 characters
long, and one used only inside multi-factor login at least 8.
Verifiers may impose no other composition rules and may not demand
periodic changes, but must force a change when there is evidence of
compromise. New passwords are checked against a blocklist of common
and breached ones, the user is told why a choice was refused, and
the stored form is salted and hashed with a scheme that has a cost
factor. Consecutive failed attempts against one authenticator are
capped at 100. For sessions at AAL2 it recommends asking again at
least every 24 hours, and after an hour without activity.

Our recommendation follows from that. Where users already hold an
account with a competent identity provider, let that provider do the
check and accept its signed answer, because a password the
application never stores is one it can never leak. Where the
application must keep passwords, follow 800-63B literally rather
than by memory, and put a phishing-resistant method in front of
anything administrative.

What it looks like in practice

When the company moved its source code onto its own git server,
authentication was the first item on the list of what running a
forge means. The forge chosen is SSH-first and has no administrative
web interface, so the way in is a key. A session that arrives
anonymously is turned away, as is one that arrives without a key,
and every declared repository is marked private besides. The
listener that checks those keys, on port 23231, accepts connections
from the loopback interface alone, so every login from outside first
passes through a jump host, and the firewall’s declared surface
stays the same size.

The same concern looks different at the scale of a whole
organisation. In an earlier role as Infrastructure Engineer, the
work was consolidating identities and access across M365, 1Password,
Red Hat SSO and OKTA SSO, where permissions had been granted ad hoc,
over time, by different people. Least privilege was enforced, and
onboarding and offboarding were standardised so that access was
revoked promptly instead of lingering after someone moved on.
Unauthorised-access risk dropped sharply and access became
auditable: the team could finally answer “who can reach this, and
why”.

Authentication also has a face, and users judge it by its error
messages. On one application’s sign-in against a major mail
provider, the message said the password was incorrect. The password
was right; the provider requires an application-specific password
for third-party clients and rejects the account password however
carefully it is typed. The message was rewritten to name the
provider, say that it requires an app-specific password for other
clients, and say where to create one. A test now drives that refusal
and asserts that the message contains the provider’s name and the
required credential type, so the old wording cannot return
unnoticed.

Where it goes wrong

  * The message blames the user for a cause elsewhere. A locked
account, an expired password, a clock drifting out of step with a
code generator and a provider demanding a different credential all
arrive as “wrong password”, and the user retypes something that will
never work. Name the cause the user can act on, while keeping the
reply identical for an account that exists and one that does not, so
the form gives nobody a list of valid usernames.

  * A phishing page relays the code in real time. The user types a
password and a six-digit code into a copy of the real page, which
forwards both to the genuine site within the 30 seconds that RFC
6238 recommends as the default time step. One-time codes stop stolen
and reused passwords; they do little against a live relay.
Origin-bound keys such as passkeys sign for one site only, which is
why NIST counts them as phishing-resistant and typed codes not.

  * Credentials outlive the people who held them. Offboarding closes
the account in the directory, while an SSH key in an
`authorized_keys` file, a personal access token and a shared
administrator password carry on working. Each credential needs an
owner, a place where it is recorded and a date when someone looks at
it again.

  * The session stays valid long after the sign-in. A cookie or
token that lasts for months is a password with a long fuse. Signing
out has to end the session on the server, not just delete the cookie
in one browser, and a self-contained token that the server never
checks back on stays usable until it expires, whatever happens to
the account.

  * Account recovery is the weakest entrance. A strong login beside
a reset link sent to an email address makes the mailbox the real
credential. Recovery deserves the same scrutiny as the front door,
because an attacker will pick whichever one is weaker.

Further reading

  * NIST SP 800-63B-4 — the current text: assurance levels, the
15-character password minimum and what counts as phishing-resistant.

  * NIST SP 800-63B, revision 3 — the 2017 authentication guideline,
kept online and marked as superseded by revision 4 from 1 August
2025.

  * RFC 9110, section 11: HTTP Authentication — the challenge and
response behind 401, WWW-Authenticate and the Authorization header.

  * RFC 4252: The SSH Authentication Protocol — public-key, password
and host-based login as SSH defines them.

  * RFC 6238: TOTP — how authenticator apps derive their short codes
from a shared secret and the clock.

  * Web Authentication, Level 3 — the W3C API behind passkeys and
its origin-scoped public-key credentials.

hThis page on the web	URL:https://engineer.company/glossary/authentication/	engineer.company	70