RAID

What it is

RAID runs several disks as a single block device, so that the group
can be faster, larger or harder to kill than any one of its members.
The name comes from a 1987 technical report from the University of
California, Berkeley, by David Patterson, Garth Gibson and Randy
Katz: _A Case for Redundant Arrays of Inexpensive Disks (RAID)_.
Linux spells the levels in lower case and without a space, raid1 or
raid5, which is how its md driver reports them.

The report starts from a mismatch. Processors and memory were
getting faster, and the abstract warns that the gain is wasted
unless input and output keep up. It sets the Single Large Expensive
Disk, or SLED, whose capacity had grown quickly while its
performance had improved only modestly, against arrays built from
the cheap disks made for personal computers, which it expects to
beat the big disk roughly tenfold on speed, reliability, power draw
and room to grow. The comparison is concrete: an IBM 3380 mainframe
disk, a Fujitsu Super Eagle for minicomputers, and the 100 MB Conner
CP 3100 for personal computers.

Then comes the catch, in a section the authors title as bad news. If
disks fail independently and at a constant rate, which the paper
notes is what disk makers assume when they quote a mean time to
failure (MTTF), an array's MTTF is that of one disk divided by the
number of disks. A hundred CP 3100s, each rated at

30,000 hours, give 300 hours, under two weeks; a thousand give 30
hours. The conclusion is blunt: “Without fault tolerance, large
arrays of inexpensive disks are too unreliable to be useful.”

The answer is redundancy. The disks are split into reliability
groups, each with extra check disks that hold redundant information.
When a disk fails, it is replaced and its contents are rebuilt onto
the new disk from that information; the time this takes is the mean
time to repair, and hot standby spares, switched in electronically
when a disk dies, shorten it. The report then lays out five
organisations and calls each one a level. Level 1 mirrors every
disk. Level 2 corrects errors with a Hamming code, as memory systems
did. Level 3 needs only a single check disk per group. Level 4 lets
small reads and writes go to separate disks at the same time. Level
5 spreads data and check information across every disk, so that no
single check disk holds up the writes.

Practice has added to the list. mdadm, the tool that manages Linux
software RAID, accepts linear, raid0 (or stripe), raid1, raid4,
raid5, raid6 and raid10, among others. Striping without redundancy,
now called level 0, is not in the

1987 taxonomy, which begins with mirrored disks. The report left
open whether an array is built in hardware or in software and called
that a question of cost and benefit alone. Linux md is the software
kind; a controller card that shows the operating system one large
disk is the hardware kind.

Why it matters

A disk wears out, and on a server with one disk its failure stops
the machine and leaves the data to whatever backup exists. The
report opens its section on reliability with exactly that: disks are
unreliable enough that systems managers back up everything every
night. With redundancy, a failed disk becomes a repair job instead
of an outage. The array carries on from the members that remain, in
a state Linux calls degraded, and returns to full strength once a
replacement has been added and rebuilt.

That protection lasts only as long as the remaining disks do. The
report's arithmetic counts data as lost when a second disk in the
same group fails before the first one has been repaired, so the
length of the repair window matters as much as the number of check
disks. With hot spares and short repairs the figures become
impressive: the report computes that a level 5 array of 1,000 disks,
in groups of ten with 5 percent standby spares, would still have an
MTTF of 90 years. Elsewhere it warns that an earthquake or a power
surge can make the disks in one array fail together, and its
formulas assume they do not.

Choosing a level is a trade between capacity, speed and cost. The
report's own conclusion is that mirrored disks suit transaction
processing that uses no more than half of the storage, and level 5
looks best when more of the capacity is needed, or for supercomputer
work, or for a mix of that and transaction processing.

When the redundancy runs out, what is left is recovery. The
portfolio entry on recovering data from SD cards, hard disks, SSDs
and RAID treats a failed RAID array as a problem of its own, set
apart from a dead SSD or a failed platter drive, with the right
approach depending on the medium.

What it looks like in practice

Take a server with one partition on each of two disks, `/dev/sda1`
and `/dev/sdb1`, to be mirrored for a data volume. With Linux md,
three commands build the array, put a file system on it and record
it in the configuration:

```sh
mdadm --create /dev/md0 --level=1 --raid-devices=2 /dev/sda1 /dev/sdb1
mke2fs -t ext4 -L data /dev/md0
mdadm --detail --scan >> /etc/mdadm/mdadm.conf
```

The first creates `/dev/md0`, a RAID1 array of the two partitions,
and the kernel starts a resync, recalculating the redundancy, as it
does after any creation. The second formats the array exactly as it
would a single disk; the file system sees one device. The third
appends a line describing the array to mdadm's configuration file,
which lives at `/etc/mdadm.conf` or `/etc/mdadm/mdadm.conf`, and the
manual asks for that output to be reviewed before use, since it may
carry detail nobody wants there.

Three files show how the array is doing:

```sh
cat /proc/mdstat
cat /sys/block/md0/md/degraded
cat /sys/block/md0/md/sync_action
```

`/proc/mdstat` lists every active md device with its state, and
mdadm reads it to find arrays and to follow reconstruction. Each
array also has a directory under `/sys/block/`, and in it `degraded`
holds the number of members missing: 0 for a whole array, 1 with one
disk gone. `sync_action` reads `idle` when nothing is happening,
`resync` after creation or an unclean shutdown, `recover` while a
hot spare takes over the contents of a lost member, and `check` or
`repair` during a full verification. Writing `check` to it starts
that verification, which reads every block of the array:

```sh
echo check > /sys/block/md0/md/sync_action
cat /sys/block/md0/md/mismatch_cnt
```

Afterwards `mismatch_cnt` gives the number of sectors that were
rewritten, or that would have been. The kernel documentation notes
that most levels work in pages rather than sectors, so the count can
be larger than the number of real errors.

Someone also has to hear about a failure. `mdadm --monitor` polls
the arrays and turns what it notices into events, which it can mail
to an address or hand to a program. On a system run by systemd, the
manual names `mdmonitor.service` as the main route, and `MAILADDR`
in `mdadm.conf` as the setting to fill in for mail. Only five events
send mail: `Fail`, `FailSpare`, `DegradedArray`, `SparesMissing` and
`TestMessage`. The last exists to prove the path works:

```text
MAILADDR ops@example.com
```

```sh
mdadm --monitor --scan --oneshot --test
mdadm --detail --test /dev/md0
```

The first sends a test message for every array it finds and then
exits. The second suits a script: with `--test`, its exit status is
0 for a healthy array,

1 when at least one device has failed, 2 when so many have failed
that the array is unusable, and 4 when mdadm hit an error while
gathering information about the array.

The array covers one event, a disk dying, and nothing else. The
portfolio entry on backup and restore-test automation describes a
separate recovery design: encrypted, deduplicated restic snapshots
to storage at another provider over SFTP, systemd timers and a
monthly workflow that restores a known file to a scratch location
and compares its bytes. That is a test of restoration in the design,
not evidence that it has run. The implementation record dated
2026-10-27 says the timers were disabled without a configured
repository and records no completed live restore.

Where it goes wrong

An array is built for one event, a member disk dying, and most of
the ways it loses data sit just beside that event.

The array is taken for a backup. A mirror writes every change to
both disks at once, and that includes a file deleted by mistake, a
table dropped by a bad migration or a volume encrypted by
ransomware. Every member then holds the same damage. The fix is a
separate backup kept off the host, with restores tested on a
schedule, so the array guards against hardware and the backup
against everything else.

A degraded array goes unnoticed. A degraded array keeps serving, and
nothing about it looks different until the next disk fails. mdadm
sends no mail unless it has an address or a program: with `--scan`
and neither configured, the manual says it monitors nothing.
`DegradedArray` also covers only arrays that are already degraded
when mdadm first sees them; a disk that dies later produces a `Fail`
event. The fix is to set `MAILADDR`, make sure `mdmonitor.service`
is running, and send a `--test` message to prove that mail arrives.

The second disk fails during the rebuild. A rebuild reconstructs the
missing disk from all the others, and the report's model loses data
exactly when another disk in the group fails within that repair
time. A failed disk left in place for a week stretches the window to
a week. The fix is to shorten it: keep a hot spare in the array,
which mdadm can set up at creation with `--spare-devices`, replace
failed disks promptly, and run a scheduled `check`, so that a disk
with problems is found while the array can still correct them.

The disks are not independent. The MTTF arithmetic assumes that
disks fail on their own, and the report itself names an earthquake
and a power surge as cases where they would not. Two disks in one
case share a power supply, a controller, a room and a building. The
fix is to treat the calculated figure as an upper bound and to cover
shared causes with something outside the box, such as a copy at
another site.

A RAID 5 or 6 array is dirty and degraded at once. If the machine
stops uncleanly while a member is missing, the parity cannot be
trusted and some blocks cannot be rebuilt, so the kernel
documentation warns of undetectable corruption, and md refuses to
start the array. Forcing it with `mdadm --assemble --force`, or for
a root file system with the `start_dirty_degraded` module parameter,
accepts that risk. The fix is to choose a consistency policy in
advance: md can log writes to a journal device for levels 4, 5 and
6, and for level 5 it offers a partial parity log, which the
documentation says closes the write hole. When forcing is the only
way in, treat the data as suspect and check it against a backup.

RAID 0 is counted as protection. md lists raid0 and linear arrays as
having no redundancy information, and mdadm's monitor reports them
with `Wrong-Level`, because they support none of the failure, spare
and resync operations it watches. There is nothing to rebuild a
missing member from. The fix is to use level 0 only for data that
can be thrown away or recreated, and never to count it as RAID in
the sense of the 1987 report.

A hardware controller hides the disks. Behind a controller card, the
operating system sees one logical device, and asking that device
about drive health reaches the controller, not the drives. smartctl,
for example, needs `-d megaraid,N` to address disk N behind a
MegaRAID controller, which its manual says also covers Dell PERC
cards. The fix is to monitor each physical disk through the
controller's own interface, so that a failing member is noticed
while the array is still whole.

Further reading

  * A Case for Redundant Arrays of Inexpensive Disks (RAID) — the
Berkeley technical report's page, with its abstract and the PDF.

  * UCB/CSD-87-391, the full report (PDF) — the MTTF arithmetic,
reliability groups and the five levels.

  * RAID arrays, Linux kernel documentation — md's files under
`/sys`, dirty degraded arrays and consistency policies.

  * mdadm(8) — creating arrays, monitor events, mail and the
`--detail --test` exit codes.

  * smartctl(8), smartmontools — reaching disks behind RAID
controllers with the `-d` option.

hThis page on the web	URL:https://engineer.company/glossary/raid/	engineer.company	70