S.M.A.R.T.

What it is

S.M.A.R.T. stands for Self-Monitoring, Analysis and Reporting
Technology; smartmontools and its manuals write it without the dots,
as SMART. It is a record a disk keeps about itself, in its own
firmware, while it works: counts of events, readings of its
condition and the results of tests it has run. The operating system
can ask the drive for that record at any time. smartmontools, the
toolkit this page draws on, says most current disks in the ATA/SATA,
SCSI/SAS and NVMe families implement this technology. The package
ships two programs: smartctl, which reads and tests one disk when
you run it, and smartd, a daemon that keeps watch in the background.

What a disk can report depends on the command set it speaks. An ATA
or SATA disk keeps a table of numbered attributes, from 1 to 253,
each with a name; attribute

12, for example, counts how many times the disk has been powered up.
Every attribute carries a raw value, the actual count or reading,
and a normalized value between 1 and 254 that the vendor's firmware
works out from the raw one by its own formula. Next to those sit the
worst normalized value the disk has recorded in its life and a
threshold chosen by the manufacturer. An attribute whose normalized
value drops to its threshold or below has failed.

Each attribute is one of two types. A pre-failure attribute at or
below its threshold says the disk is about to fail. An old-age
attribute, also called a usage attribute, at or below its threshold
says the disk has reached the end of its life through ordinary wear.
The smartctl manual stresses that the Pre-fail label is no cause for
worry by itself: it only carries that meaning once the value has
crossed the threshold.

Above the table sits one verdict, the health status. An ATA disk
answers a command named SMART RETURN STATUS with pass or fail. A
SCSI or SAS disk reports through an exceptions log page and its
sense data, and an NVMe drive sets bits in the Critical Warning byte
of its SMART/Health Information log. Disks can also test themselves
on request: a short test, usually done in under ten minutes, a long
one that takes anything from tens of minutes to several hours, and
on ATA disks a conveyance test aimed at damage from transport. The
outcome of each lands in a self-test log on the disk.

Why it matters

A disk sees its own trouble before anyone else does. It knows which
of its sectors no longer read, how often it has been switched on and
how hot it runs. S.M.A.R.T. is the channel through which that
knowledge reaches the people responsible for the data, and
smartmontools describes the payoff modestly: in many cases, it says,
the tools give “advanced warning of disk degradation and failure”.
Many cases is not all of them, and much of this page is about that
difference.

The strongest signal is the verdict. When smartctl reports a failing
health status, its manual says the disk has either failed already or
expects to fail within the next 24 hours, and tells the reader to
collect the full report and move the data somewhere safe without
delay. Weaker signals come earlier. A pending sector is one the disk
wants to mark as bad and swap for a spare, typically because a read
from it failed; a non-zero count means some data on the disk is no
longer readable. The disk counts those sectors in attribute 197, and
in attribute 198 it counts sectors that neither an offline scan nor
a self-test managed to read.

None of this helps if nobody looks. smartd switches S.M.A.R.T.
monitoring on for ATA disks, polls the disks every 30 minutes by
default, reports errors and attribute changes to syslog and can send
a warning by email. It can also start self-tests on a schedule, so
no cron job is needed for that part. The project is old and still
moving: it marked the 20th anniversary of its first release in
October 2022, released version 7.5 on 30 April 2025, and moved its
development from SourceForge to GitHub on 1 June 2025. It runs on
Linux, the BSDs, macOS, Solaris and Windows, among others.

What it looks like in practice

Take a new server with a SATA disk at `/dev/sda`. Three commands
give the picture:

```sh
smartctl -i /dev/sda
smartctl -H /dev/sda
smartctl -A /dev/sda
```

The first prints the model, serial number and firmware, whether the
drive supports S.M.A.R.T. and whether it is switched on, and whether
the drive is listed in the smartmontools drive database. The second
prints the verdict. The third prints the attribute table: VALUE and
WORST hold the normalized numbers, THRESH the threshold, TYPE says
Pre-fail or Old_age, RAW_VALUE holds the raw count, and WHEN_FAILED
says `FAILING_NOW`, `In_the_past` or a dash for an attribute that
has never failed. When you want everything in one go, `smartctl -x`
prints all the information the tool can read, S.M.A.R.T. and
otherwise, with the table in a denser layout.

A long self-test is the more thorough version of the short one:

```sh
smartctl -t long /dev/sda
smartctl -l selftest /dev/sda
```

Unless `-C` asks for captive mode, the test runs inside the disk
while the system carries on with its work. It can slow the drive
down, heavy traffic from the operating system makes it take longer,
and only one test runs at a time. The manual adds that a shutdown in
the middle should do no harm, since the test is either aborted or
resumed. The second command reads the self-test log once the
estimated time has passed.

Scripts should read the exit status rather than the text. smartctl
builds it from eight bits, and the manual's own example tests bit 3,
which is set when the disk reports that it is failing:

```sh
smartctl -q silent -H /dev/sda
smartstat=$(($? & 8))
```

`-q silent` prints nothing, so the exit status is the only answer. A
non-zero status does not always mean a dying disk: bit 6 alone, for
instance, means only that the error log holds entries.

For the long run, smartd reads its rules from `smartd.conf`. One
line can cover every disk the scan finds:

```text
DEVICESCAN -a -s (S/../.././02|L/../../6/03) -W 2,40,45 \
  -m ops@example.com -M test
```

`-a` turns on the standard set: the health status, the error and
self-test logs, failed usage attributes, changes in attribute values
and, on ATA disks, the counts in attributes 197 and 198. The `-s`
pattern starts a short test every day between 02:00 and 03:00 and a
long one every Saturday between 03:00 and 04:00. `-W 2,40,45`
reports a temperature change of 2 degrees, logs a note at 40 °C and
raises a critical warning, by syslog and email, at 45 °C. `-m` names
the recipient, and `-M test` sends one test message when smartd
starts. After an edit, `killall -HUP smartd` makes the daemon read
the file again.

Numbers like these matter most while the disk still answers. Our
portfolio entry on recovering data from failed storage starts after
that point: between 2003 and 2014, people brought in memory cards,
hard drives, SSDs and RAID arrays that had already failed, and the
method had to suit the particular kind of medium.

Where it goes wrong

A passing verdict is read as a clean bill. The health status only
says the disk has not declared itself failed. Attributes can be at
or below their thresholds now or in the past, and pending sectors
can already hold unreadable data, while the verdict still reads as
passed. The fix is to read the attribute table and the self-test log
as well, let smartd report attributes 197 and 198, and keep backups
that do not rely on the disk's opinion of itself.

Raw values are taken at face value. The standard does not say how a
raw value maps to a physical unit. The smartctl manual mentions a
Hitachi disk that counts power-on time in minutes rather than hours,
and IBM disks that keep three temperatures in their raw values.
Since revision 4 of ATA/ATAPI-4 the meaning of the attributes has
been left entirely to vendors, and solid-state drives give some
numbers other meanings, so the printed name can be wrong unless the
drive is in the database. The fix is to compare a disk with its own
history, not with a different model, and to check what `-i` says
about the database before trusting a name.

`-a` is used on an ATA disk. It was the classic way to see
everything, but the manual no longer recommends it for ATA, because
it leaves out the options that need 48-bit ATA commands, such as the
extended error log. The fix is to use `-x`.

A RAID controller hides the disks. The operating system sees one
logical drive, which has nothing useful to report, and smartd's
automatic scan on Linux leaves out disks behind RAID controllers
altogether. The fix is to address each physical disk through the
controller, with the matching device type: `-d megaraid,N` reaches
disk N behind a MegaRAID or Dell PERC controller on Linux and
FreeBSD, and a line such as `/dev/sda -d megaraid,0 -a` in
`smartd.conf` puts that disk under watch.

A USB enclosure sits in the way. USB storage speaks the SCSI command
set to the computer but nearly always holds an ATA or SATA disk or
flash memory. The manual names bridge firmware, along with RAID
controllers, as a layer that can leave the health status unknown,
and smartctl then warns and falls back to comparing pre-failure
attributes with their thresholds. The fix is to try `-d sat`, which
wraps the ATA commands in the SCSI-to-ATA translation standard; `-d
sat,12` selects the shorter of its two command forms.

The warning email never arrives. smartd sends mail with the system's
`mail` command, which has to be on the path of the environment
smartd was started from. If it is missing, the warning exists only
in syslog. The fix is `-M test`, then checking that the test message
has actually landed in an inbox someone reads; `-M exec` can point
smartd at another mailer or a script.

A test schedule never fires. In the `-s` pattern, month, day of the
month and hour each take two digits. A pattern such as `S/../.././2`
never matches, and the manual warns about exactly that. The fix is
to write `02`, and to read the log after the first night to see that
a test ran.

A broken edit goes unnoticed. When smartd reloads its configuration
on a hang-up signal and finds a syntax error, it prints the error
and carries on with the old rules, as though the signal never came.
The fix is to read the log after every reload, or restart the
service, since smartd refuses to start at all with a faulty file.

Temperature goes unwatched. All temperature reports are off by
default, and `-a` does not turn them on. The fix is to add `-W` with
limits that suit the hardware.

A check wakes a sleeping disk. A disk spun down to save power will
spin up when smartctl talks to it. The fix, for scripts that run
often, is `-n standby`, which makes smartctl exit with status 2
instead of waking the disk, or `-n standby,0` to treat that case as
success.

Further reading

  * smartmontools — the project's home page: both programs,
supported systems and release news.

  * smartctl(8), manual page source — attributes, thresholds, health
status, self-tests, device types, exit bits.

  * smartd(8), manual page source — the daemon: polling, syslog,
signals and how it scans for disks.

  * smartd.conf(5), manual page source — directives for monitoring,
test schedules, temperature limits and email.

hThis page on the web	URL:https://engineer.company/glossary/smart/	engineer.company	70